Control · Peak Smoothing

Pass the tip without turning the auxiliary light back on

On cold mornings, all substations send requests at the same time. Dyneo dynamically utilizes the thermal inertia of buildings and the grid: it preheats before peak demand, then briefly lowers the setpoints of the substations sending the most requests.

Demonstration network. Illustrative values.

The Principle

Why is the tip so expensive?

Peak power determines the capacity of your facilities and often triggers the use of peak-load generation—the most expensive and highest-emission source of heat in the grid. Just a few hours each winter have a significant impact on production costs and the carbon footprint.

Without steering

Everyone raises at the same time

At 6 a.m., the controllers come out of night standby mode and the hot water tanks begin to refill. All the substations send requests at the same time, and the power plant must respond.

With hair straightening

Demand is spread out

The buildings with the highest demand are preheated before peak hours, and then their setpoint is lowered briefly. Their thermal inertia does the rest: your customers don't notice the difference.

Field Results

−20% of the network's total peak load

Achieved by controlling only the 20% of substations that draw the most power.

Why is so little enough?

A few shoppers are out and about

In a power grid, a small number of buildings account for the bulk of the power demand. The measurements taken at each substation make it possible to identify these buildings and focus on them first.

The Key Point

Thermal inertia, used dynamically

Buildings and the grid store heat. Smoothing out peak demand does not mean turning off the heat; rather, it involves charging this thermal inertia before the peak and releasing it during the peak, recalculating the optimal time and amount each day.

01

Front-loading

When heat is available, the selected buildings and the network warm up slightly. The heat is stored in the walls, floor slabs, and pipes.

02

Return within

During peak hours, their power demand decreases. The stored heat takes over, and the indoor temperature remains stable.

03

Recalculate every day

The time and height of the peak vary depending on the weather. Each building reacts differently. Therefore, the timing and dosage are recalculated day by day, building by building.

The Method

Four Steps, from Forecast to Results

01

Planning for Peak Demand

The demand and the weather forecast for the next few hours indicate when the peak will occur and how high it will be.

02

Selecting Substations

Those that require the most power and in which the building retains heat well. Often, just a few are enough.

03

Preheat, then set aside

A brief warm-up before peak demand, followed by a brief reduction in the setpoint, within the limits agreed upon with you.

04

Check

The power drawn at the power plant, the feedback, and—when measured—the internal temperatures confirm the result.

The Levers

Where to Find Flexibility

Building Inertia

A well-insulated building loses very little heat in an hour. It can be preheated and then left to run on its own during peak hours.

Grid Inertia

Tap water is a reserve. A slightly higher flow rate before peak demand loads the system without triggering the makeup pump.

Storage

A balloon charged at night using base heat covers part of the morning peak.

Domestic Hot Water

The refilling of hot water tanks can be moved up or delayed by a few tens of minutes without affecting the occupants.

Morning Follow-ups

Scheduling reminders to occur after the overnight lull prevents them all from falling within the same 15-minute period.

Start Instructions

Coordinate with production management so that the power plant can anticipate rather than react.

Learn about production management →

Frequently Asked Questions

What business owners are asking of us

Will our customers be cold?

The temperature fluctuation is brief, preceded by a warm-up period, and limited to the thresholds set with you for each substation. The building's thermal mass keeps the indoor temperature stable.

Should all substations be controlled?

No. In practice, managing the 20% of substations that draw the most power was enough to reduce the overall peak by 20%.

Should we replace our PLCs?

No. Your controllers retain their programs. Dyneo offers a controlled setpoint offset, and you can stop it at any time.

Where is the data processed?

The platform is developed in Geneva and hosted in Europe. Your data remains yours.

See how our customers use it: case studies →

They operate their networks using Dyneo

  • Veolia Logo – Dyneo Client
  • Romande Energie Logo – Dyneo Client
  • SIEL42 Logo – Dyneo Client
  • Val-de-Ruz Municipality Logo – Dyneo client
  • Genolier Logo – Dyneo Client
  • CADouest Logo – Dyneo Client
  • CADcime Logo – Dyneo Client
  • Viteos Logo – Dyneo Client
  • SIL Logo, Lausanne Industrial Services – Dyneo client
  • Edifea Logo – Dyneo Client