Advertise · Detection and Diagnosis

Identify problems with your network before they cost you money

Dyneo continuously compares the readings from each substation with what they should be. When a deviation persists, you know where it is, what the likely cause is, how much it costs, and what to do.

Demonstration network. Illustrative values.

The Principle

FDD, Applied to a Thermal Network

FDD stands for Fault Detection and Diagnostics. The method originates from the construction and industrial sectors. We apply it to heating and cooling networks, from the production stage all the way to your customers’ substations.

An alarm

Means that a threshold has been crossed

It is triggered by a fixed value, ignores weather conditions and historical data, and often occurs in batches of dozens. The cause must still be investigated manually.

A diagnosis

Explain why, and what to do

He compares the measurement to what it should be under the current conditions, cross-references related measurements to identify the likely cause, and calculates the cost of the defect.

The Method

Four Steps, from Assessment to Intervention

01

Detect

Each measurement is compared to its expected behavior, based on the outdoor temperature, the time of day, and the substation's history. A persistent deviation is classified as an anomaly.

02

Diagnose

Measurements from adjacent areas are cross-referenced to pinpoint the likely cause: valve, heat exchanger, control system, meter, or secondary circuit.

03

Prioritize

Each issue is classified based on its impact on grid feedback, energy loss, and your customers' comfort. You should address the most costly issues first.

04

Take Action and Verify

The recommended action is forwarded to the relevant team. After the work is completed, tests confirm that the defect has been corrected.

What We Detect

The problems that have the greatest impact on a district heating system

Control valve

Stuck open, unstable, or incorrectly sized. Sign: a return line that is too hot and a flow rate that no longer meets demand.

Fouled heat exchanger

The gap between the primary and secondary circuits is widening month by month. This indicates that more flow is needed for the same power.

Water Law

If it's set too high, it overheats the building and increases the return flow. If it's set too low, it leads to complaints of discomfort.

Bypass and Excessive Flow

Hot water that flows back without having released its heat. Indicator: a small difference between the supply and return temperatures.

A meter or sensor that is drifting

One incorrect measurement throws off everything else, right down to the bill. The sign: a discrepancy between production and substations that can no longer be reconciled.

Domestic Hot Water

Improperly adjusted loop control, cycles that are too short, or incorrect DHW priority settings. Symptoms: flow rate spikes and hot return water at night.

Our Approaches

The Right Approach for Every Defect

A

Business Rules

Farmers’ expertise translated into rules: a return value above the contractual target, a round-trip deviation that is too small. Simple, clear, and immediate.

B

Physical Models

The laws of heat transfer provide the expected value for a heat exchanger or a circuit. Any deviation from the model indicates wear.

C

Data-Driven Learning

The history of each substation provides insight into its normal behavior. Any deviation from this behavior stands out, even without a predefined rule.

D

Combined Approach

The three complement each other: learning provides context, while rules and models provide explanations. That is what makes a diagnosis actionable.

First, reliable measurements

A diagnosis is only as good as the data it is based on

Before looking for a fault, we check the measurements: holes, fixed values, reversed probes, and meters that drift. An anomaly detected in a false measurement is useless.

Fewer alerts, more decisions

A short list, ranked by impact

Instead of hundreds of alerts, your teams receive only the anomalies that matter, along with the substation, the probable cause, and the recommended action.

Frequently Asked Questions

What business owners are asking of us

Should we install new sensors?

Generally speaking, no. We start with the data you already have: monitoring systems, substation controllers, and energy meters. If any data is missing for a diagnostic assessment, we'll let you know.

How is this different from the alarms in my monitoring system?

The monitoring system indicates that a threshold has been exceeded. The diagnostic process takes current conditions into account, identifies the likely cause, and classifies the anomalies by impact.

Who works in the field?

Your teams or your maintenance engineer, just like today. Dyneo tells them where to go and what to check, then verifies through the measurements that the defect has been corrected.

Where is the data processed?

The platform is developed in Geneva and hosted in Europe. Your data remains yours.

See how our customers use it: case studies →

They operate their networks using Dyneo

  • Veolia Logo – Dyneo Client
  • Romande Energie Logo – Dyneo Client
  • SIEL42 Logo – Dyneo Client
  • Val-de-Ruz Municipality Logo – Dyneo client
  • Genolier Logo – Dyneo Client
  • CADouest Logo – Dyneo Client
  • CADcime Logo – Dyneo Client
  • Viteos Logo – Dyneo Client
  • SIL Logo, Lausanne Industrial Services – Dyneo client
  • Edifea Logo – Dyneo Client